Home > Logging Cable > 7-Conductor >
7-Conductor
Cable Diameter | 0.325” +0.005” - 0.002” | (8.25mm + 0.13mm -0.05mm) |
Minimum Sheave Diameter | 18” | (45 cm) |
Cable Stretch Coeffcient | 1.8 ft/Kft/Klbs | (2.02 m/km/5KN) |
Maximum Conductor Voltage | 1000 VDC | |
Conductor AWG Rating | 22 | |
Minimum Insulation Resistance | 1,500 MegΩ/Kft @ 500VDC | (457 MegΩ/Km @ 500VDC) |
Armor Electrical Resistance | 2.3 Ω/Kft | (7.5 Ω/Km) |
Cable Breaking Strength Ends Fixed |
9,500 lbs | (42 KN) Nominal |
Maximum Suggested Working Tension | 4,750 lbs | (21 KN) |
Number and Size of Wires | ||
Inner Armor | 18 x 0.0320” | (0.81 mm) |
Outer Armor | 18 x 0.0445” | (1.13 mm) |
Average Wire Breaking Strength | ||
Inner Armor | 217 lbs | (0.97 KN) |
Outer Armor | 420 lbs | (1.99 KN) |
Cable Type | Core Description | Cable Weight | ||||||||
Temp Rating °F °C |
Plastic Type |
Insulation Thickness in mm |
Copper Construction in mm |
Res. Typical Ω/Kft Ω/Km |
Cap. Typical pf/ft pf/m |
O.D. Each in mm |
Tape Type |
in Air |
in H2O |
|
lbs/Kft Kg/Km |
||||||||||
7H32RP |
300 149 |
Poly |
0.013 0.33 |
7x0.0100 7x0.254 |
15.8 51.8 |
55 180 |
0.056 1.42 |
Dacron |
183 272 |
152 226 |
7H32RZ |
500 260 |
ETFE |
0.013 0.33 |
7x0.0100 7x0.254 |
15.8 51.8 |
67 220 |
0.056 1.42 |
Nomex |
188 280 |
157 234 |