Home > Logging Cable > Monoconductor >
Monoconductor
Cable Diameter | 0.288” +0.005” - 0.002” | (7.32mm + 0.13mm -0.05mm) |
Minimum Sheave Diameter | 16” | (41 cm) |
Cable Stretch Coeffcient | 1.55 ft/Kft/Klbs | (1.74 m/Km/5KN) |
Maximum Conductor Voltage | 1,500 VDC | |
Conductor AWG Rating | 15 | |
Minimum Insulation Resistance | 1,500 Mega Ω/Kft @ 500VDC | (457 Mega Ω/Km @ 500VDC) |
Armor Electrical Resistance | 2.8 Ω/Kft | (9.2 Ω/Km) |
Cable Breaking Strength Ends Fixed |
10,200 lbs | (45.4 KN) Nominal |
Maximum Suggested Working Tension | 5,100 lbs | (22.7 KN) |
Number and Size of Wires | ||
Inner Armor | 12 x 0.0400” | (1.016 mm) |
Outer Armor | 18 x 0.0400” | (1.016 mm) |
Average Wire Breaking Strength | ||
Inner Armor | 393 lbs | (1.75 KN) |
Outer Armor | 393 lbs | (1.75 KN) |
Cable Type | Core Description | Cable Weight | |||||||
Temp Rating °F °C |
Plastic Type |
Insulation Thickness in mm |
Copper Construction in mm |
Res Typical Ω/Kft Ω/Km |
Cap. Typical pf/ft pf/m |
O.D. Each in mm |
in Air |
in H2 O |
|
lbs/Kft Kg/Km |
|||||||||
1N29PP-EHS |
300 149 |
Poly |
0.0325 0.826 |
19.0x0.0142 19.0x0.361 |
2.8 9.2 |
56 184 |
0.136 3.454 |
152 226 |
125 187 |
1N29PTZ-EHS |
500 260 |
FEP ETFE |
0.0135 0.343 0.019 0.483 |
19x0.0142 19x0.361 |
2.8 9.2 |
55 177 |
0.098 2.489 0.136 3.454 |
157 234 |
130 193 |
1N29PA-EHS |
500 260 |
PFA |
0.0325 0.826 |
19x0.0142 19x0.361 |
2.8 9.2 |
51 167 |
0.136 3.454 |
159 237 |
131 196 |
Any cable inquiry please feel free to contact us.