7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 PROPERTIES
Cable Diameter: 0.224” +0.005” - 0.002” (5.69mm + 0.13mm -0.05mm)
Minimum Sheave Diameter: 14” (36 cm)
Cable Stretch Coeffcient: 2.7 ft/Kft/Klbs (3.0 m/Km/5KN)
7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 ELECTRICAL
Maximum Conductor Voltage: 1,200 VDC
Conductor AWG Rating: 18
Minimum Insulation Resistance: 1,500 Mega Ω/Kft @ 500VDC (457 Mega Ω/Km @ 500VDC)
Armor Electrical Resistance: 16.0 Ω/Kft (52.5 Ω/Km)
7/32” (5.69 mm) MONOCONDUCTOR, CORROSION RESISTANT 1K22 S75 MECHANICAL
Cable Breaking Strength
Ends Fixed: 4,700 lbs (20.9 KN) Nominal
Maximum Suggested Working Tension: 2,350 lbs (10.5 KN)
Number and Size of Wires
Inner Armor: 15 x 0.0243” (0.617 mm)
Outer Armor: 15 x 0.0358” (0.909 mm)
Average Wire Breaking Strength
Inner Armor : 111 lbs (0.50 KN)
Outer Armor : 242 lbs (1.10 KN)
Cable Type |
Core Description |
Cable Weight |
|
Temp
Rating
°F
°C |
Plastic
Type |
Insulation
Thickness
in
mm |
Copper
Construction
in
mm |
Res
Typical
Ω/Kft
Ω/Km |
Cap.
Typical
pf/ft
pf/m |
O.D.
Each
in
mm |
in
Air |
in
H2O |
lbs/Kft
Kg/Km |
1K22SA-S75 |
See
Below |
PFA |
0.0305
0.775 |
7x0.0159
7x0.404 |
6.7
22.0 |
43
141 |
0.108
2.743 |
95
142 |
78
117 |
Insulation is rated to 500°F. Armor wires are rated to 325° F at low exposure to H2S + CO2.
The armor wires are made of a corrosion resistant alloy steel. Wires are preformed.
The nickel coated copper wires are made of ASTMB355 Class 10 and they are used to increase corrosion protection.
Core assembly – Copper strand consists of six wires around one center wire. Conductor resistance is measured at 68° F.
Voids in the copper strand are flled with a water-blocking agent to reduce water and gas migration.
SUPERSEAL, a special pressure seal agent, is applied between armor layers.
The insulation temperature rating assumes a normal gradient for both temperature and weight.
All values shown are nominal or typical values.