Home > Logging Cable > Monoconductor >
Monoconductor
Cable Diameter | 0.322” +0.005” - 0.002” | (8.18mm + 0.13mm -0.05mm) |
Minimum Sheave Diameter | 18” | (46 cm) |
Cable Stretch Coeffcient | 1.2 ft/Kft/Klbs | (1.35 m/Km/5KN) |
Maximum Conductor Voltage | 1,500 VDC | |
Conductor AWG Rating | 13 | |
Minimum Insulation Resistance | 1,500 Mega Ω/Kft @ 500VDC | (457 Mega Ω/Km @ 500VDC) |
Armor Electrical Resistance | 2.1 Ω/Kft | (6.9 Ω/Km) |
Cable Breaking Strength Ends Fixed |
12,000 lbs | (53.3 KN) Nominal |
Maximum Suggested Working Tension | 6,000 lbs | (26.6 KN) |
Number and Size of Wires | ||
Inner Armor | 12 x 0.0445” | (1.130 mm) |
Outer Armor | 18 x 0.0445” | (1.130 mm) |
Average Wire Breaking Strength | ||
Inner Armor | 442 lbs | (1.97 KN) |
Outer Armor | 442 lbs | (1.97 KN) |
Cable Type | Core Description | Cable Weight | |||||||
Temp Rating °F °C |
Plastic Type |
Insulation Thickness in mm |
Copper Construction in mm |
Res Typical Ω/Kft Ω/Km |
Cap. Typical pf/ft pf/m |
O.D. Each in mm |
in Air |
in H2O |
|
lbs/Kft Kg/Km |
|||||||||
1N32PTZ-LR |
500 260 |
FEP ETFE |
0.017 0.432 0.018 0.444 |
19x0.0172 19x0.437 |
2.3 7.5 |
58 190 |
0.120 3.048 0.155 3.937 |
198 294 |
163 243 |
Any cable inquiry please feel free to contact us.
Send EmailMonoconductor Cable
3-Conductor
4-Conductor
7-Conductor
Any cable inquiry please feel free to contact us.
Email: huadong@hdcablegroup.com
Whatsapp:+86 13939070673